Percutaneous Thrombolytic Device
Percutaneous, mechanical thrombolysis for dialysis AV synthetic grafts and AV native fistulae:
-
Conforms to graft and fistula walls without the risk of wall damage
-
Operates with a touch of an ON/OFF switch
-
No capital equipment required
-
No clinical hemolysis, reduces procedural holding time
-
Maximizes thrombus removal
-
Product can be easily visualized under fluoroscopy
-
Easy thrombus aspiration from the patient
-
Long length allows for a variety of access points
-
Provides ability to pass the device over a wire

ARROWg+ard Blue
Antiseptic infection protection for central venous catheters and percutaneous sheath introducers.
Product line includes ARROWg+ ard® (outside protection only ) on 14 and 16 gauge single lumen catheters, 4 French through 12 French double, triple and quad lumen CVCs, and 8.5 and 9.0 French PSIs, including the MAC™. ARROWg+ ard® Blue PLUS™ technology has intraluminal and extraluminal antimicrobial protection.

Rapid Infusion Catheter
A 7 (RC-09700) and 8.5 (RC-09850) French catheter exchange set for transitioning from a 20 gauge or larger peripheral IV to large bore access in emergency settings or in the pre-operative anesthesia setting:
-
Provides secure access to existing peripheral IV site
-
Provides for maximum flow in a peripheral vein
-
Easily stored

Balloon Cholangiography Catheterization Set
4 French, 60cm Karlan™ Balloon Catheter packaged either with (CS 01700) or without (CS 01701) a 5mm metal introducer for performing a cholangiogram:
-
When inflated properly, the balloon occludes the cystic duct.
-
Provides two access routes
-
Provides a highly visible marker on the catheter
-
Will not obstruct visibility of duct
-
Directs the catheter at an angle once inside the abdomen
-
Provides a seal once trocar assembly is removed

Thermodilution Catheter
The Arrow Thermodilution catheter is a flow directed (balloon flotation) and/or torque controlled catheter used to measure right heart pressures, and measure cardiac output through placement of the catheter in the pulmonary artery:
-
Reduces the risk of catheter contamination and clinician exposure to bloodborne pathogens
-
Provides a simple mechanism for checking the patency of the balloon with less risk of contamination
-
Better maneuverability at femoral insertion site,does not soften as quickly in situ
-
Reduces thrombus formation on catheter surface
-
The diameter of the deflated balloon does not exceed the diameter of the catheter body,allowing equal sizing of the catheter to sheath (7 Fr.catheter
-
goes through a 7 Fr.sheath),minimizes vessel trauma and blood loss thru the use of the smallest sheath possible.
-
Truer waveforms when monitoring (The smaller the distal lumen,the more the waveform will be distorted).
-
Less kinking than PVC which can dampen waveforms
-
Reduces the risks associated with PVC (poly vinyl chloride) catheter materials, such as clot formation
